PURGE VALVE > INSPECTION |
| 1. INSPECT DUTY VACUUM SWITCHING VALVE |
Check the resistance.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
Check the operation.
![]() |
Check that air does not flow from port E to port F.
| Condition | Specified Condition |
| No continuity | There is no air flow |
![]() |
Apply battery voltage across the terminals to check that air flows from port E to port F.
| Condition | Specified Condition |
| With continuity | There is air flow |